Grid-Connected PV Cabinet
For grid-connected photovoltaic projects that need AC distribution, metering, combiner or grid-connection protection between inverters and the grid side, when the project needs a project-ready grid-connected PV equipment with PV capacity configuration of 100-800 kW. What it does:
Grid-Connected PV Cabinet collects, distributes or connects PV system output while integrating switching, surge protection, metering and enclosure options according to project scale. It supports voltage options including 690V AC, 400V AC and 690VAC. The product is positioned for procurement teams that need clear model selection, technical confirmation and export project coordination. Why buyers choose it:
- Available PV capacity configuration of 100-800 kW helps match common project loads without changing the product family.
- Selectable voltage options including 690V AC, 400V AC and 690VAC supports coordination with site distribution systems.
- model reference 100 / 200 / 300 / 400 / 500 / 600 / 800 kW, IP30 / IP65 protection gives engineers a clear basis for technical comparison and specification review.
- The product can be coordinated with Longxiang switchgear, transformer, new-energy equipment or project accessories for packaged delivery.
- Product data support clearer communication for overseas tendering, distributor quotation and technical review. Before quotation:
Please confirm PV capacity, AC voltage, inverter circuit quantity, input and output circuits, metering requirement, enclosure material, installation method and protection degree.
Application Scenarios
Selection & Delivery Notes
- Voltage: 690V AC / 400V AC | Capacity: 100 / 200 / 300
- Confirm the required voltage level, rated capacity, frequency, and installation environment.
- Share the destination country, quantity, project schedule, and whether drawings or technical documents are required.
- Use the inquiry form on this page so the sales and engineering team can reply with a matched configuration.
Product Parameter
| Capacity | 100/200/300/400/500/600/800 |
| Model range | 100 / 200 / 300 / 400 / 500 / 600 / 800 kW |
| Maximum input voltage | 690VAC |
| Measured data | Three-phase current, three-phase voltage, active power, apparent power, power factor, frequency and energy |
| Communication | RS485 bus / standard MODBUS-RTU protocol |
| Input circuits | Customized according to user requirements |
| Output circuits | 1 |
| Rated AC voltage | 400V |
| Maximum rated input current | 250A / 400A / 630A / 800A / 1000A / 1250A / 1600A |
| Frequency | 50Hz/60Hz |
| Meter connection | Secondary connection |
| Enclosure material | Hot-dip galvanized steel, stainless steel or cold-rolled steel |
| Protection degree | IP30 / IP65 |
| Enclosure size | Customized |
| Isolation switch / frame breaker | 690V AC, 250A-1600A |
| Residual-current protection breaker | 4P, 690V AC, 250A-800A |
| Over-voltage setting | Phase voltage 250-320V adjustable |
| Under-voltage setting | Phase voltage 145-200V adjustable |
| Phase-loss protection | <50V |
| AC surge protector | 400V AC, 40kA maximum discharge current |
| Molded-case circuit breaker | 690V AC, rated current selected according to user requirements |
| Operating temperature | -20C to +60C |
| Operating humidity | <=90%RH, non-condensing |
| Altitude | <=2000m; derating required above 2000m |
| Installation | Floor-mounted |
| Optional function | Anti-islanding device |
Project & Export Support
Product FAQ
Can Longxiang support custom voltage or capacity?
Yes. Custom specifications are available on request after engineers review the project requirements.
Can I request OEM or project-matched equipment?
Project matching and OEM-style requirements can be discussed with the sales and engineering team.
Can these products be supplied for Middle East, Africa, or Southeast Asia projects?
Longxiang can discuss overseas project requirements and provide technical selection support. Final export documents and terms should be confirmed with sales.
How do I get a quotation?
Send the product type, country, quantity or project scale, and required voltage or capacity. Engineers will review the requirement before quotation.