KYN28-12 Indoor Metal-Clad Withdrawable Switchgear
For medium-voltage distribution rooms in power plants, industrial facilities, mining enterprises, substations and motor-control projects.
What it doesKYN28-12 is an indoor metal-clad withdrawable switchgear for 3.6-12 kV three-phase AC 50 Hz single-busbar or sectionalized single-busbar systems. It supports power receiving, distribution, control, protection, measurement and circuit monitoring.
Why buyers choose it- Withdrawable design helps inspection and maintenance without redesigning the whole switchroom.
- Rated voltage options cover 3 kV, 6 kV, 7.2 kV and 12 kV systems.
- Rated current up to 3150 A supports demanding medium-voltage distribution projects.
- Can be equipped with VD4 or VS1 vacuum circuit breakers according to project preference.
- IP4X enclosure and IP2X protection when compartment doors are open improve site safety.
Please confirm system voltage, rated current, short-circuit breaking current, busbar scheme, breaker brand preference, incoming/outgoing circuit quantity, protection relay requirements and project standard.
Application Scenarios
Selection & Delivery Notes
- Voltage: 3kV / 6kV / 7.2kV | Capacity: 3kV, 6kV, 7.2kV, 12kV | Standard: IEC 298, GB 3906, DL/T 404
- Confirm the required voltage level, rated capacity, frequency, and installation environment.
- Share the destination country, quantity, project schedule, and whether drawings or technical documents are required.
- Use the inquiry form on this page so the sales and engineering team can reply with a matched configuration.
Product Parameter
| Product Model | KYN28-12 |
| Switchgear Type | Indoor metal-clad withdrawable switchgear |
| Rated Voltage | 3kV, 6kV, 7.2kV, 12kV |
| Rated Frequency | 50Hz |
| Circuit Breaker Rated Current | 630A, 1250A, 1600A, 2000A, 2500A, 3150A |
| Switchgear Rated Current | 630A, 1250A, 1600A, 2000A, 2500A, 3150A |
| Rated Dynamic Stable Current | 16kA, 20kA, 25kA, 31.5kA, 40kA, 50kA |
| Rated Peak Withstand Current | 40kA, 50kA, 63kA, 80kA, 100kA, 125kA |
| Rated Short-Circuit Breaking Current | 16kA, 20kA, 25kA, 31.5kA, 40kA, 50kA |
| Insulation Level | 1min power-frequency withstand voltage 24/32/42kV; lightning impulse withstand voltage 40/60/75kV |
| Protection Rating | Enclosure IP4X, compartment and circuit-breaker door open IP2X |
| Ambient Temperature | -10°C to +40°C |
| Altitude | ≤1000m |
| Standards | IEC 298, GB 3906, DL/T 404 |
Project & Export Support
Product FAQ
Can Longxiang support custom voltage or capacity?
Yes. Custom specifications are available on request after engineers review the project requirements.
Can I request OEM or project-matched equipment?
Project matching and OEM-style requirements can be discussed with the sales and engineering team.
Can these products be supplied for Middle East, Africa, or Southeast Asia projects?
Longxiang can discuss overseas project requirements and provide technical selection support. Final export documents and terms should be confirmed with sales.
How do I get a quotation?
Send the product type, country, quantity or project scale, and required voltage or capacity. Engineers will review the requirement before quotation.