Segmented Multi-Chamber Arc-Quenching Surge Arrester (Active Arc-Quenching)
For 6-35 kV overhead distribution lines that need stronger lightning-trip prevention, especially pole-mounted line sections exposed to lightning-induced transient overvoltage, pollution, condensation or severe outdoor service conditions.
What it doesThe segmented multi-chamber arc-quenching surge arrester uses built-in arc-quenching valve plates in each chamber to actively extinguish lightning power-frequency follow-current arcs. It does not require coordination with substation auto-reclosing equipment. The fully enclosed core arc-quenching unit helps protect the device from contamination and condensation, while the resistor-free full-air arc passage increases lightning-current carrying capability and reduces thermal-breakdown risk.
Why buyers choose it- Active arc-quenching design helps significantly reduce lightning-induced tripping on distribution lines.
- Segmented multi-chamber structure creates multi-angle and multi-layer arc breakpoints for reliable arc compression, stretching and extinction.
- Fully enclosed structure improves tolerance to pollution, condensation and harsh outdoor environments.
- Resistor-free full-air dielectric arc channel supports high current carrying capability and low residual voltage performance.
- 10 kV models support live-line installation, reducing outage losses during construction.
- Type-tested product family covers 10 kV and 35 kV models and supports optional discharge counters and remote monitoring devices.
Please confirm voltage class, line type, pole arrangement, installation quantity, altitude, ambient conditions, live-line installation requirement, and whether discharge counters or remote monitoring devices are needed.
Application Scenarios
Selection & Delivery Notes
- Voltage: 0.2kV for GDMH-10/5.0; 0.6kV for GDMH-35/5.0 | Standard: GB 1984-2003; IEC 62271-100:2001
- Confirm the required voltage level, rated capacity, frequency, and installation environment.
- Share the destination country, quantity, project schedule, and whether drawings or technical documents are required.
- Use the inquiry form on this page so the sales and engineering team can reply with a matched configuration.
Product Parameter
| Product Model | GDMH-10/5.0 / GDMH-35/5.0 |
| Product Type | Segmented multi-chamber arc-extinguishing lightning protection device |
| Arc-extinguishing Current Threshold | 20kV |
| Arc-extinguishing Times | 1000 times |
| Response Time | 0.003ms |
| Arc-extinguishing Time | 8ms |
| Residual Voltage | 0.2kV for GDMH-10/5.0; 0.6kV for GDMH-35/5.0 |
| Weight | 1kg for GDMH-10/5.0; 1.8kg for GDMH-35/5.0 |
| Maintenance-free Cycle | 5 years |
| Altitude | Below 4500m |
| Operating Conditions | -30C to +70C; seismic intensity grade 8 and below |
| High Current Impulse Withstand | 100kA |
| Installation Method | One arrester unit on each A, B and C phase conductor for every utility pole |
| Earthing / Jumper Requirement | No jumper wires or earthing connections required |
| Optional Devices | Discharge counters and remote monitoring devices |
| Reference Standards | GB 1984-2003; IEC 62271-100:2001 |
| Voltage Class | 6-35 kV |
| Voltage Class | 10 kV |
| Voltage Class | 35 kV |
Project & Export Support
Product FAQ
Can Longxiang support custom voltage or capacity?
Yes. Custom specifications are available on request after engineers review the project requirements.
Can I request OEM or project-matched equipment?
Project matching and OEM-style requirements can be discussed with the sales and engineering team.
Can these products be supplied for Middle East, Africa, or Southeast Asia projects?
Longxiang can discuss overseas project requirements and provide technical selection support. Final export documents and terms should be confirmed with sales.
How do I get a quotation?
Send the product type, country, quantity or project scale, and required voltage or capacity. Engineers will review the requirement before quotation.